Garden valve with vacuum valve and plastic handle
PROPERTIES
- Self-draining
- With vacuum valve and plastic handle
- With approved non-return valve
- Frost-proof even if the hose/coupling is connected
- Can be cut to suit wall thickness
- Wall bracket: H=106 mm, W=66 mm, diagonal screw holes
- Approved backflow prevention device, EN-Standard EN 1717
No. | FMM No. | RSK | Description |
---|---|---|---|
1 | 37570400 | 4316710 | Spindle, L=400 mm |
1 | 37570600 | 4316711 | Spindle, L=600 mm |
1 | 37571000 | 4316712 | Spindle, L=1000 mm |
2 | 37551000 | 4316708 | Valve body with cone and nut |
3 | 39144300 | 4316713 | Fastening details |
4 | 29815000 | 5045393 | Chrome, 10 pcs |
4 | 29815009 | 5045391 | Chrome |
5 | 35160009 | 4316706 | Headwork for loose key, retail packed |
6 | 35160019 | 4316707 | Headwork for loose handle, retail packed |
7 | 42760009 | 4316714 | Key, retail packed |
8 | 42770000 | 4316715 | Handle |
9 | 37590000 | Screw M5x6 | |
10 | 37580000 | 5438346 | Valve cone kit for spindle 3757 |
11 | 37801790 | 8314140 | O-ring 17,3 x 2,4, 2 pcs |
12 | 37521000 | Guiding ring, 3 pcs |
modal.bvb.desc;
Accepted installation instructions
Safe Water Installation (Säker Vatteninstallation) is a set of industry* regulations to safeguard the quality of sanitary installations, prevent injury and damage and ensure compliance with the building regulations of the Swedish National Board of Housing, Building and Planning (Boverket).
Leadfree
Lead Free means that we have eliminated the lead that is normally found in brass alloys. This will reduce environmental impact of the products. Products classified as Lead Free contain less than 0.1 % lead.
Energyclass
Energy labelling is an objective rating system that shows exactly how much energy a mixer uses. The system was developed by a number of players including sanitary fittings manufacturers, building companies, property owners and authorities such as the Swedish Energy Agency. It is based on standardised laboratory tests and certification rules. Its aim is simple: to offer impartial help for buyers, installation firms, air conditioning consultants and consumers. The mixer’s energy performance is assessed by measuring and registering water pressure, mixed water temperature and flushing time for twelve different activities. The values registered for each of these activities are added together to obtain a total energy consumption value, which is displayed on the label. This total value determines the mixer’s energy rating.
modal.sundahus.title
modal.sundahus.desc